Cassettes - V7 series. The ultimate solution for business premises that offers efficiency and flexibility!

  • Incomparable flexibility and uniform air distribution throughout the space with the Independent Louver Swing
  • Fresh air intake for clean and healthy environment
  • Ability to extend the air conditioning to an additional room thanks to the External Air Duct Outlet
  • Built-in drain pump which servs every kind of installation
  • Absolute control of the air conditioner from wherever you are

Contact us

Eurovent"

Inventor air conditioners present the innovative air-conditioning unit management "HOTEL MENU". The HOTEL MENU is a set of features specifically designed to help better and more economical operation of air conditioners installed in hotel units.

The technological superiority of the series guarantees excellent performances with the lowest operating costs. Take advantage of the highest energy class A+++ of Inventor air conditioners and create the perfect atmosphere exactly as you dream. At the same time save money while also taking care of the energy footprint by choosing an air conditioner with lower energy consumption.

The ultimate protection of the air conditioner, especially at areas with high humidity levels and increased corrosive possibility, such as islands and coastal areas, can now be achieved. The golden, anticorrosive coating of the outdoor unit’s refrigerant, protects against salty air, rain and other corrosive elements, ensuring the effective performance of the air conditioner and the extension of its lifeline. The golden coating of the indoor unit refrigerant, thanks to its antibacterial action, allows you to enjoy a perfectly clean and healthy atmosphere!

The centralized multi-functional device can control up to 64 indoor units within a maximum connection length of 1200m. Control your air conditioner, set the temperature you want and select the mode you desire. Ideal for hotel & business units. *Refers to the units of 24.000~60.000btu/h

The variety of options provided by the pre-installed ON/OFF contact gives you the flexibility you need to manage your air conditioners, while saving time and energy. Install Door Switch or remote switches to turn units on or off easily and instantly.

A smart sensor is located on the remote control. When the Follow Me function is activated the set temperature synchronizes with the smart sensor. Your set temperature will follow you wherever you and the remote go, offering extra comfort and energy savings.

Enjoy optimum comfort, anywhere in the room. 360 degree directional wind coming out from 8 instead of 4 air outlets, can deliver air evenly throughout every corner in any space.

Complete your connected products portfolio by integrating Inventor air conditioners into your BMS (Building Management System). Create an integrated ecosystem that includes air conditioning, ventilation, lighting, and security systems, fully alignment with your building's needs. Enjoy quick, easy, and efficient management of all these different systems through central management and achieve optimum efficiency and comfort in your building. *Requires separate purchase of connection kit

Benefit from the Weekly Planner and set the air conditioner’s operating period according to your needs, ensuring maximum energy and money savings. The new advanced wired controller indicates the error codes and enables you to set the room temperature sensor via the wired controller instead of the air conditioner unit.

Take the whole control of you unit! Thanks to the error code that will appear if an error occurs, you can always be safe and sure for the appropriate and most efficient operation of your air conditioner.

With the new ECO mode on your remote controller, you can set your air conditioner to operate at the lowest cost, achieving maximum energy savings & enjoying the greatest conditions in your place.

With the GEAR function you achieve great energy savings, limiting the maximum consumption of the unit. You can adjust the performance in two stages, at 75% of maximum efficiency and 50%. Take care of the right temperature in your space, reducing operating costs.

The iClean function ensures the best air quality in your space, removing accumulated dust, mold and bacteria from inside the unit.

Set the unit to start and stop automatically in a 24h period.

Enjoy excellent temperature conditions and tranquil atmosphere. The advanced design of the unit, featuring larger gaps between air ducts and an improved fan tilt, facilitates airflow and ensures quiet, efficient performance. Additionally, Silent Mode further reduces noise levels, allowing you to enjoy a perfect atmosphere undisturbed.

With the Sleep Mode, the air conditioner adjusts the room temperature for perfect sleeping conditions and great energy savings.

This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.

Enjoy the flexibility offered by the Delay function, postponing the activation of the weekly schedule for up to 3 hours. Change your device settings for a specific day without changing your weekly schedule settings.

Ensure the operation of your appliance in cooling or heating without interference. With the locking feature, the operation of the air conditioner cannot be changed, avoiding incorrect settings, and offering a more correct and economical operation. Ideal for workplaces or hotel rooms.

Turn off the ability to use the wireless controller to adjust your air conditioner to ensure central control of the device from a single point. Suitable for business premises and hotels.

The perceived temperature by the indoor unit sensor may vary from the real temperature of the room, due to the position of the unit. Thanks to this function you can minimize the difference and achieve better conditions in your place.

Indoor fan speed is regulated automatically from the lowest grade to the setting grade according to the evaporator temperature when the unit starts heating operation.

The outdoor unit’s special design produces an efficient and effective cooling operation even at -15°C.

Excellent heating performance even at the most demaning regions with low temperature levels. Ensure the prefered temperature conditions, even at -15°C and enjoy ideal conditions in your place.

Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.

If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

Indoor unit will show error code “EC” and will stop automatically when refrigerant leakage is detected.

Want to turn off the AC beep and display? By pressing the mute operation, Inventor AC helps to give you a quiet and comfortable night.

Engage the lock function to prevent anyone from changing the settings or children playing with the unit.

The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.

The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.

  • MODEL V7CRI-12WiFiR / U7RS-12
  • Cooling Capacity 12.000 (2.897-14.020) Btu / h
  • Cooling Capacity Range 3.52 (0.85-4.11) kWatt
  • Heating Capacity 13.000 (1.604-14.705) Btu / h
  • Heating Capacity 3.81(0.47-4.31) kWatt
  • Seasonal Efficiency Cooling In accordanceto EN14825
  • Pdesign 3.5 kW
  • Energy Class A++ kW
  • SEER 6.6
  • Seasonal Efficiency Heating (Middle Zone) In accordanceto EN14825
  • Pdesign 2.7 kW
  • Energy Class A+ kW
  • SCOP 4.1
  • Seasonal Efficiency Heating (Warm Zone) In accordanceto EN14825
  • Pdesign 3.3 kW
  • Energy Class A+++ kW
  • SCOP 5.1
  • Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
  • Current Input Cooling 4.45 (1.32-6.31) A
  • Current Input Heating 4.73 (1.04-6.07)
  • Power Input Cooling 1.01 (0.17-1.43) kW
  • Power Input Heating 1.02 (0.12-1.38) kW
  • Air Flow Volume (High / Medium / Low) 620/510/420 m³ / h
  • Noise Level Indoor unit 25.5/33/36/41 Low / Medium / High
  • Noise Level Outdoor unit 53.6 dB(A)
  • Sound Power Level Indoor / Outdoor unit 57/62 dB(A)
  • Power Supply Wire Outdoor / Fuses 3x2.5/1x16 No x mm² / Α
  • Signal Wires 4 x 1.5 No x mm²
  • Dimensions WxDxH Panel 647x647x50 mm
  • Dimensions WxDxH Indoor unit 570x570x260 mm
  • Dimensions WxDxH Outdoor unit 765x303x555 mm
  • Net Weight Panel / Indoor / Outdoor 2.5/16.3/26.6 kg
  • Liquid line - Gas line 1/4" | 3/8" °C
  • Refrigerant / Charge R32/710 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50/-15~24 °C
  • MODEL V7CRI-18WiFiR / U7RS-18
  • Cooling Capacity 18.000 (9.900-19.064) Btu / h
  • Cooling Capacity Range 5.28 (2.90-5.59) kWatt
  • Heating Capacity 19.000 (8.100-20.800) Btu / h
  • Heating Capacity 5.57 (2.37-6.10) kWatt
  • Seasonal Efficiency Cooling In accordanceto EN14825
  • Pdesign 5.3 kW
  • Energy Class A++ kW
  • SEER 6.3
  • Seasonal Efficiency Heating (Middle Zone) In accordanceto EN14825
  • Pdesign 4.2 kW
  • Energy Class A+ kW
  • SCOP 4.0
  • Seasonal Efficiency Heating (Warm Zone) In accordanceto EN14825
  • Pdesign 5.4 kW
  • Energy Class A++ kW
  • SCOP 4.8
  • Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
  • Current Input Cooling 7.20 (3.20-9.20) A
  • Current Input Heating 6.80 (3.10-8.50)
  • Power Input Cooling 1.63 (0.72-2.09) kW
  • Power Input Heating 1.54 (0.70-1.93) kW
  • Air Flow Volume (High / Medium / Low) 720/620/500 m³ / h
  • Noise Level Indoor unit 29/35.5/39.5/43 Low / Medium / High
  • Noise Level Outdoor unit 56 dB(A)
  • Sound Power Level Indoor / Outdoor unit 59/65 dB(A)
  • Power Supply Wire Outdoor / Fuses 3x2.5/1x16 No x mm² / Α
  • Signal Wires 4 x 1.5 No x mm²
  • Dimensions WxDxH Panel 647x647x50 mm
  • Dimensions WxDxH Indoor unit 570x570x260 mm
  • Dimensions WxDxH Outdoor unit 805x330x554 mm
  • Net Weight Panel / Indoor / Outdoor 2.5/16.3/26.6 kg
  • Liquid line - Gas line 1/4" | 1/2" °C
  • Refrigerant / Charge R32/1.150 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50/-15~24 °C
  • MODEL V7CI-24WiFiR / U7RS-24
  • Cooling Capacity 24.000 (11.263-27.000) Btu / h
  • Cooling Capacity Range 7.03 (3.30-7.91) kWatt
  • Heating Capacity 26.000 (9.577-30.500) Btu / h
  • Heating Capacity 7.62 (2.81-8.94) kWatt
  • Seasonal Efficiency Cooling In accordanceto EN14825
  • Pdesign 7.0 kW
  • Energy Class A++ kW
  • SEER 6.2
  • Seasonal Efficiency Heating (Middle Zone) In accordanceto EN14825
  • Pdesign 6.0 kW
  • Energy Class A+ kW
  • SCOP 4.0
  • Seasonal Efficiency Heating (Warm Zone) In accordanceto EN14825
  • Pdesign 6.3 kW
  • Energy Class A+++ kW
  • SCOP 5.1
  • Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
  • Current Input Cooling 10.20 (4.20-12.00) A
  • Current Input Heating 8.50 (3.60-12.10)
  • Power Input Cooling 2.32 (0.78-2.75) kW
  • Power Input Heating 1.90 (0.61-2.70) kW
  • Air Flow Volume (High / Medium / Low) 1.300/1.140/1.000 m³ / h
  • Noise Level Indoor unit 27/39.5/42.5/45.5 Low / Medium / High
  • Noise Level Outdoor unit 60 dB(A)
  • Sound Power Level Indoor / Outdoor unit 59/69 dB(A)
  • Power Supply Wire Outdoor / Fuses 3x2.5/1x16 No x mm² / Α
  • Signal Wires 4 x 1.5 No x mm²
  • Dimensions WxDxH Panel 950x950x55 mm
  • Dimensions WxDxH Indoor unit 830x830x205 mm
  • Dimensions WxDxH Outdoor unit 890x342x673 mm
  • Net Weight Panel / Indoor / Outdoor 6.0/21.6/43.9 kg
  • Liquid line - Gas line 3/8" | 5/8" °C
  • Refrigerant / Charge R32/1.500 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50/-15~24 °C
  • MODEL V7CI-36WiFiR / U7RS-36
  • Cooling Capacity 36.000 (9.200-39.000) Btu / h
  • Cooling Capacity Range 10.55 (2.70-11.43) kWatt
  • Heating Capacity 38.000 (9.500-42.000) Btu / h
  • Heating Capacity 11.14(2.78-12.30) kWatt
  • Seasonal Efficiency Cooling In accordanceto EN14825
  • Pdesign 10.5 kW
  • Energy Class A++ kW
  • SEER 6.7
  • Seasonal Efficiency Heating (Middle Zone) In accordanceto EN14825
  • Pdesign 8.5 kW
  • Energy Class A+ kW
  • SCOP 4.0
  • Seasonal Efficiency Heating (Warm Zone) In accordanceto EN14825
  • Pdesign 10.1 kW
  • Energy Class A+++ kW
  • SCOP 5.1
  • Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
  • Current Input Cooling 17.50 (4.20-18.50) A
  • Current Input Heating 13.50 (3.50-17.50)
  • Power Input Cooling 3.95 (0.90-4.20) kW
  • Power Input Heating 3.70 (0.75-4.25) kW
  • Air Flow Volume (High / Medium / Low) 1.700/1.550/1.380 m³ / h
  • Noise Level Indoor unit 39/44.5/47.5/50 Low / Medium / High
  • Noise Level Outdoor unit 63 dB(A)
  • Sound Power Level Indoor / Outdoor unit 64/70 dB(A)
  • Power Supply Wire Outdoor / Fuses 3x4.0 / 1x25 No x mm² / Α
  • Signal Wires 4 x 1.5 No x mm²
  • Dimensions WxDxH Panel 950x950x55 mm
  • Dimensions WxDxH Indoor unit 830x830x205 mm
  • Dimensions WxDxH Outdoor unit 946x410x810 mm
  • Net Weight Panel / Indoor / Outdoor 6.0/21.6/43.9 kg
  • Liquid line - Gas line 3/8" | 5/8" °C
  • Refrigerant / Charge R32/2.400 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50/-15~24 °C
  • MODEL V7CI-42WiFiR / U7RS-42
  • Cooling Capacity 41.000 (10.000-42.000) Btu / h
  • Cooling Capacity Range 12.02(2.93-12.31) kWatt
  • Heating Capacity 46.000 (11.500-48.000) Btu / h
  • Heating Capacity 13.48(3.37-14.07) kWatt
  • Seasonal Efficiency Cooling In accordanceto EN14825
  • Pdesign 12.1 kW
  • Energy Class A++ kW
  • SEER 6.1
  • Seasonal Efficiency Heating (Middle Zone) In accordanceto EN14825
  • Pdesign 9.5 kW
  • Energy Class A+ kW
  • SCOP 4.0
  • Seasonal Efficiency Heating (Warm Zone) In accordanceto EN14825
  • Pdesign 9.8 kW
  • Energy Class A+++ kW
  • SCOP 5.1
  • Voltage / Frequency / Phase 220-240/50/1 V / Hz / Ph
  • Current Input Cooling 18.80 (3.10-19.10) A
  • Current Input Heating 16.30 (3.40-19.00)
  • Power Input Cooling 4.20 (0.68-4.35) kW
  • Power Input Heating 3.70 (0.75-4.25) kW
  • Air Flow Volume (High / Medium / Low) 1.900/1.750/1.600 m³ / h
  • Noise Level Indoor unit 38/46/48.5/51 Low / Medium / High
  • Noise Level Outdoor unit 63 dB(A)
  • Sound Power Level Indoor / Outdoor unit 66/72 dB(A)
  • Power Supply Wire Outdoor / Fuses 3x4.0 / 1x25 No x mm² / Α
  • Signal Wires 4 x 1.5 No x mm²
  • Dimensions WxDxH Panel 950x950x55 mm
  • Dimensions WxDxH Indoor unit 830x830x205 mm
  • Dimensions WxDxH Outdoor unit 946x410x810 mm
  • Net Weight Panel / Indoor / Outdoor 6.0/21.6/43.9 kg
  • Liquid line - Gas line 3/8" | 5/8" °C
  • Refrigerant / Charge R32/2.800 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50/-15~24 °C
  • MODEL V7CI-50WiFiR / U7RT-50
  • Cooling Capacity 48.000 (12.000-54.000) Btu / h
  • Cooling Capacity Range 14.07(3.52-15.83) kWatt
  • Heating Capacity 55.000 (14.000-59.000) Btu / h
  • Heating Capacity 16.12(4.10-17.29) kWatt
  • Seasonal Efficiency Cooling In accordanceto EN14825
  • Pdesign 14.0 kW
  • Energy Class A++ kW
  • SEER 6.1
  • Seasonal Efficiency Heating (Middle Zone) In accordanceto EN14825
  • Pdesign 11.0 kW
  • Energy Class A+ kW
  • SCOP 4.0
  • Seasonal Efficiency Heating (Warm Zone) In accordanceto EN14825
  • Pdesign 12.0 kW
  • Energy Class A++ kW
  • SCOP 5.0
  • Voltage / Frequency / Phase 380-415/50/3 V / Hz / Ph
  • Current Input Cooling 8.10 (1.80-10.20) A
  • Current Input Heating 8.00 (1.90-9.50)
  • Power Input Cooling 4.65 (0.80-5.90) kW
  • Power Input Heating 4.58 (0.90-5.50) kW
  • Air Flow Volume (High / Medium / Low) 1.970/1.780/1.580 m³ / h
  • Noise Level Indoor unit 37.5/46.5/48.5/51 Low / Medium / High
  • Noise Level Outdoor unit 63.5 dB(A)
  • Sound Power Level Indoor / Outdoor unit 66/74 dB(A)
  • Power Supply Wire Outdoor / Fuses 5x2.5 / 3x16 No x mm² / Α
  • Signal Wires 4 x 1.5 No x mm²
  • Dimensions WxDxH Panel 950x950x55 mm
  • Dimensions WxDxH Indoor unit 830x830x205 mm
  • Dimensions WxDxH Outdoor unit 952x415x1.333 mm
  • Net Weight Panel / Indoor / Outdoor 6.0/21.6/43.9 kg
  • Liquid line - Gas line 3/8" | 5/8" °C
  • Refrigerant / Charge R32/2.900 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50/-15~24 °C
  • MODEL V7CI-60WiFiR / U7RT-60
  • Cooling Capacity 53.000 (14.000-57.000) Btu / h
  • Cooling Capacity Range 15.24 (4.10-16.71) kWatt
  • Heating Capacity 62.000 (15.000-68.000) Btu / h
  • Heating Capacity 18.17 (4.40-19.93) kWatt
  • Seasonal Efficiency Cooling In accordanceto EN14825
  • Pdesign 15.3 kW
  • Energy Class A++ kW
  • SEER 6.3
  • Seasonal Efficiency Heating (Middle Zone) In accordanceto EN14825
  • Pdesign 11.9 kW
  • Energy Class A+ kW
  • SCOP 4.0
  • Seasonal Efficiency Heating (Warm Zone) In accordanceto EN14825
  • Pdesign 12.5 kW
  • Energy Class A+++ kW
  • SCOP 5.1
  • Voltage / Frequency / Phase 380-415/50/3 V / Hz / Ph
  • Current Input Cooling 8.60 (2.10-10.70) A
  • Current Input Heating 9.60 (2.10-10.70)
  • Power Input Cooling 5.00 (0.98-6.20) kW
  • Power Input Heating 5.55 (1.2-6.70) kW
  • Air Flow Volume (High / Medium / Low) 2.000/1.850/1.650 m³ / h
  • Noise Level Indoor unit 40/48/50.5/53 Low / Medium / High
  • Noise Level Outdoor unit 64 dB(A)
  • Sound Power Level Indoor / Outdoor unit 66/75 dB(A)
  • Power Supply Wire Outdoor / Fuses 5x2.5 / 3x16 No x mm² / Α
  • Signal Wires 4 x 1.5 No x mm²
  • Dimensions WxDxH Panel 950x950x55 mm
  • Dimensions WxDxH Indoor unit 830x830x205 mm
  • Dimensions WxDxH Outdoor unit 952x415x1.333 mm
  • Net Weight Panel / Indoor / Outdoor 6.0/21.6/43.9 kg
  • Liquid line - Gas line 3/8" | 5/8" °C
  • Refrigerant / Charge R32/3.000 g
  • Outdoor Operation Temperature Range Cooling / Heating -15~50/-15~24 °C

Useful files of cassettes V7 series

Energy Labels, User - Installation Manuals - Wireless Remote Control - Wi-Fi, Product Fiche, CE Declaration, High Resolution Photos, Technical Specifications & Features

Find more

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …