Features
Become an Inventor Partner
More
Anti-Cold Air Function
Indoor fan speed is regulated automatically from the lowest grade to the setting grade according to the evaporator temperature when the unit starts heating operation.
Low Ambient Cooling
The outdoor unit’s special design produces an efficient and effective cooling operation even at -15°C.
Excellent Heating Performance Under -15°C
Excellent heating performance even at the most demaning regions with low temperature levels. Ensure the prefered temperature conditions, even at -15°C and enjoy ideal conditions in your place.
Smart Touch Panel
You can adjust the ideal temperature in your place as well as the desired operation thanks to the touch panel of the floor standing that ensures ultimate comfort and flexibility in use.
Golden Fin
The ultimate protection of the air conditioner, especially at areas with high humidity levels and increased corrosive possibility, such as islands and coastal areas, can now be achieved. The golden, anticorrosive coating of the outdoor unit’s refrigerant, protects against salty air, rain and other corrosive elements, ensuring the effective performance of the air conditioner and the extension of its lifeline. The golden coating of the indoor unit refrigerant, thanks to its antibacterial action, allows you to enjoy a perfectly clean and healthy atmosphere!
24-hour Timer
Set the unit to start and stop automatically in a 24h period.
Auto Swing Louver
This function refers to the automatic flaps’ movement. The automatic operation enables you to manage a distribution of the air in the room.
Louver Position Memory
Horizontal louver will automatically move to the same position as you set last time when the unit turned on.
Auto Restart
If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.
Auto Error Diagnosis
Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.
Turbo Mode
This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.
Lock
Engage the lock function to prevent anyone from changing the settings or children playing with the unit.
All DC Inverter
The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.
Technical Specifications
- V6FI-60 / V6FO-60
- Cooling Capacity 48.000 (12.000-53.500) Btu / h
- Cooling Capacity 14.07 (3.52-15.68) kWatt
- Heating Capacity 55.000 (14.000-61.000) Btu / h
- Heating Capacity 16.12 (4.10-17.88) kWatt
- EER 2.84
- COP 3.16
-
Seasonal Efficiency (In accordance
to ΕΝΗ825) Cooling - Pdesign 14.0 kW
- Energy Class A++
- SEER 6.1
-
Seasonal Efficiency (In accordance
to ΕΝΗ825) Heating Middle Zone - Pdesign 10.8 kW
- Energy Class Α+
- SCOP 3.7
-
Seasonal Efficiency (In accordance
to ΕΝΗ825) Heating Warm Zone - Pdesign 11.0 kW
- Energy Class A+++
- SCOP 5.1
- Voltage / Frequency / Phase 380-415 / 50 / 3 V / Hz / Ph
- Current Input - Cooling 8.00 (1.90-10.30) Α
- Current Input - Heating 8.50 (1.90-10.50) Α
- Power Input - Cooling 4.95 (0.90-5.95) kW
- Power Input - Heating 5.10 (1.00-6.20) kW
- Air Flow Volume - Indoor Unit (High/Medium/Low) 2.413/2.222/2.027 m³ / h
- Air Flow Volume - Outdoor Unit 7.500 m³ / h
- Noise Level - Indoor unit (Low/Medium/High) 47 / 49 / 53 dB (A)
- Noise Level - Outdoor unit 67 dB (A)
- Sound Power Level - Indoor/Outdoor unit 67/72 dB (A)
- External Unit Melting Fuses 3 x 25 Α
- Internal Unit Melting Fuses - Α
- Signal Wires 4x1.5 No x mm²
- Dimensions WxDxH - Indoor unit 629x456x1.935 mm
- Dimensions WxDxH - Outdoor unit 952x415x1.333 mm
- Net Weight - Indoor / Outdoor 58.4 / 106.7 kg
- Liquid line | Gas line 3 / 8” - 5 / 8”
- Refrigerant / Charge R32 / 2.900 g
- Outdoor Operation Temperature Range - Cooling/Heating -15~50 / -15~24 °C
Media Library for Floor Standing V6FI-60
User & Installation, RC Manuals - Energy Label - High Resolution Photos
Find more
All you need to know about
Register now using your e-mail and get all the latest news in the world of air conditioning and more …