Features/ Technologies
Remote On/Off
The variety of options provided by the pre-installed ON/OFF contact gives you the flexibility you need to manage your air conditioners, while saving time and energy. Install Door Switch or remote switches to turn units on or off easily and instantly.
Central Control
Centralized (for up to 64 indoor units), front desk, touch pad wired controller, wifi and many others.
BMS Connectivity
Complete your connected products portfolio by integrating Inventor air conditioners into your BMS (Building Management System). Create an integrated ecosystem that includes air conditioning, ventilation, lighting, and security systems, fully alignment with your building's needs. Enjoy quick, easy, and efficient management of all these different systems through central management and achieve optimum efficiency and comfort in your building. *Requires separate purchase of connection kit
Ultra Silence Mode
Activate the Ultra Silence Mode and enjoy an absolute feeling of pure silence in your room.
Low Ambient Cooling at -20°C
The outdoor unit’s special design produces an efficient and effective cooling operation even at -20°C.
Low Ambient Heating at -20°C
The outdoor unit’s special design produces an efficient and effective heating operation even at -20°C.
High Density Air Dust Filter
The exquisite filter optimizes the filtering effect by 40%.
24-hour Timer
Set the unit to start and stop automatically in a 24h period.
Sleep Mode
With the Sleep Mode, the air conditioner adjusts the room temperature for perfect sleeping conditions and great energy savings.
Auto Swing Louver
Distributes cool/warm air to maximum area by moving horizontal flaps automatically.
Louver Position Memory
Horizontal louver will automatically move to the same position as you set last time when the unit turned on.
Anti-Cold Air Function
Indoor fan speed is regulated automatically from the lowest grade to the setting grade according to the evaporator temperature when the unit starts heating operation.
Turbo Mode
This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.
Auto Restart
If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.
Auto Error Diagnosis
Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.
Refrigerant Leakage Detect
Indoor unit will show error code “EC” and will stop automatically when refrigerant leakage is detected.
Two-way Draining
Both left and right sides of the indoor unit are possible for drainage hose connection, easy for installation.
All DC Inverter
The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.
R32 ECO Refrigerant
The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.
Technical Specifications
- DR2VI-09WFI/ DR2VO-09
- Cooling Capacity 9.000 (2.730-12.620) Btu / h
- Cooling Capacity 2.6 (0.8-3.2) kWatt
- Heating Capacity 11.000 (2.730-14.330) Btu / h
- Heating Capacity 3.2 (0.8-4.2) kWatt
-
Seasonal Efficiency
(In accordance to EN14825) - Cooling
- Pdesign 2.6 kW
- Energy Class A+++
- SEER 8.5
- Annual Power Consumption 107 kWh / year
- Heating Middle Zone
- Pdesign 2.4 kW
- Energy Class A++
- SCOP 4.6
- Annual Power Consumption 731 kWh / year
- Heating Warm Zone
- Pdesign 2.3 kW
- Energy Class A+++
- SCOP 5.1
- Annual Power Consumption 631 kWh / year
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input - Cooling 2.9 (0.9-6.7) Α
- Current Input - Heating 3.6 (1.3-7.2) Α
- Power Input - Cooling 0.65 (0.2-1.5) W
- Power Input - Heating 0.8 (0.3-1.6) W
- Air Flow Volume (Turbo/High/Medium/Low) 650/600/500/450 m³ / h
-
Noise Level - Indoor unit
(Silent/Low/Medium/High) 20/25/30/35 db(A) - Noise Level - Outdoor unit 47 db(A)
- Sound Power Level - Indoor unit 54 db(A)
- Sound Power Level - Outdoor unit 59 db(A)
- Dehumidifying Volume 1.2 L/h
- Dehumidifying Volume 28.8 L/day
- Compressor Type ROTARY
- Liquid line | Gas line 1 / 4” - 3 / 8”
- Fuses 10 A
- Signal Wires 4x1.5 No x mm²
-
Dimensions - Indoor unit
(WxDxH) 887x211x281 mm -
Dimensions - Outdoor unit
(WxDxH) 800x280x550 mm -
Net Weight -
Indoor/Outdoor 10.0/29.0 kg - Refrigerant/Charge R32/650 g
-
Outdoor Operation
Temperature Range - Cooling -20~43 °C -
Outdoor Operation
Temperature Range - Heating -20~24 °C
- DR2VI-12WFI/ DR2VO-12
- Cooling Capacity 12.000 (3.410-13.650) Btu / h
- Cooling Capacity 3.5 (1.0-4.0) kWatt
- Heating Capacity 14.500 (3.410-17.740) Btu / h
- Heating Capacity 4.2 (1.0-5.2) kWatt
-
Seasonal Efficiency
(In accordance to EN14825) - Cooling
- Pdesign 3.5 kW
- Energy Class A+++
- SEER 8.5
- Annual Power Consumption 144 kWh / year
- Heating Middle Zone
- Pdesign 2.8 kW
- Energy Class A++
- SCOP 4.6
- Annual Power Consumption 854 kWh / year
- Heating Warm Zone
- Pdesign 2.8 kW
- Energy Class A+++
- SCOP 5.1
- Annual Power Consumption 768 kWh / year
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input - Cooling 3.9 (1.4-6.7) Α
- Current Input - Heating 5.0 (1.3-7.2) Α
- Power Input - Cooling 0.87 (0.3-1.5) W
- Power Input - Heating 1.1 (0.5-1.6) W
- Air Flow Volume (Turbo/High/Medium/Low) 700/650/550/500 m³ / h
-
Noise Level - Indoor unit
(Silent/Low/Medium/High) 22/29/33/38 db(A) - Noise Level - Outdoor unit 48 db(A)
- Sound Power Level - Indoor unit 56 db(A)
- Sound Power Level - Outdoor unit 61 db(A)
- Dehumidifying Volume 1.6 L/h
- Dehumidifying Volume 38.4 L/day
- Compressor Type ROTARY
- Liquid line | Gas line 1 / 4” - 3 / 8”
- Fuses 10 A
- Signal Wires 4x1.5 No x mm²
-
Dimensions - Indoor unit
(WxDxH) 887x211x281 mm -
Dimensions - Outdoor unit
(WxDxH) 800x280x550 mm -
Net Weight -
Indoor/Outdoor 10.0/31.5 kg - Refrigerant/Charge R32/940 g
-
Outdoor Operation
Temperature Range - Cooling -20~43 °C -
Outdoor Operation
Temperature Range - Heating -20~24 °C
- DR2VI32-18WFI/ DR2VO32-18
- Cooling Capacity 18.000 (4.430-19.790) Btu / h
- Cooling Capacity 5.0 (1.30-5.80) kWatt
- Heating Capacity 18.150 (4.770-20.470) Btu / h
- Heating Capacity 5.2 (1.4-6.0) kWatt
-
Seasonal Efficiency
(In accordance to EN14825) - Cooling
- Pdesign 5.0 kW
- Energy Class A++
- SEER 6.1
- Annual Power Consumption 287 kWh / year
- Heating Middle Zone
- Pdesign 4.6 kW
- Energy Class A+
- SCOP 4.0
- Annual Power Consumption 1.610 kWh / year
- Heating Warm Zone
- Pdesign 4.6 kW
- Energy Class A+++
- SCOP 5.1
- Annual Power Consumption 1.263 kWh / year
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input - Cooling 6.5 (1.8-8.9) Α
- Current Input - Heating 6.3 (2.3-11.3) Α
- Power Input - Cooling 1.46 (0.4-2.0) W
- Power Input - Heating 1.4 (0.5-2.5) W
- Air Flow Volume (Turbo/High/Medium/Low) 1.000/900/800/600 m³ / h
-
Noise Level - Indoor unit
(Silent/Low/Medium/High) 30/35/40/44 db(A) - Noise Level - Outdoor unit 53 db(A)
- Sound Power Level - Indoor unit 59 db(A)
- Sound Power Level - Outdoor unit 65 db(A)
- Dehumidifying Volume 2.0 L/h
- Dehumidifying Volume 48.0 L/day
- Compressor Type ROTARY
- Liquid line | Gas line 1 / 4” - 1 / 2”
- Fuses 16 A
- Signal Wires 4x1.5 No x mm²
-
Dimensions - Indoor unit
(WxDxH) 1.030x233x322 mm -
Dimensions - Outdoor unit
(WxDxH) 800x280x550 mm -
Net Weight -
Indoor/Outdoor 13.0/32.7 kg - Refrigerant/Charge R32/900 g
-
Outdoor Operation
Temperature Range - Cooling -20~43 °C -
Outdoor Operation
Temperature Range - Heating -20~24 °C
- DR2VI32-24WFI/ DR2VO32-24
- Cooling Capacity 24.000 (7.500-29.000) Btu / h
- Cooling Capacity 7.0 (2.2-8.5) kWatt
- Heating Capacity 28.000 (8.190-34.120) Btu / h
- Heating Capacity 8.1 (2.40-10.0) kWatt
-
Seasonal Efficiency
(In accordance to EN14825) - Cooling
- Pdesign 7.0 kW
- Energy Class A++
- SEER 7.1
- Annual Power Consumption 350 kWh / year
- Heating Middle Zone
- Pdesign 5.6 kW
- Energy Class A+
- SCOP 4.0
- Annual Power Consumption 1.963 kWh / year
- Heating Warm Zone
- Pdesign 5.6 kW
- Energy Class A+++
- SCOP 5.1
- Annual Power Consumption 1.537 kWh / year
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input - Cooling 9.6 (3.2-13) Α
- Current Input - Heating 9.7 (3.2-13) Α
- Power Input - Cooling 2.16 (0.7-2.9) W
- Power Input - Heating 2.18 (0.7-2.9) W
- Air Flow Volume (Turbo/High/Medium/Low) 1.300/1.200/1.000/850 m³ / h
-
Noise Level - Indoor unit
(Silent/Low/Medium/High) 30/37/43/47 db(A) - Noise Level - Outdoor unit 52 db(A)
- Sound Power Level - Indoor unit 60 db(A)
- Sound Power Level - Outdoor unit 65 db(A)
- Dehumidifying Volume 2.8 L/h
- Dehumidifying Volume 67.2 L/day
- Compressor Type ROTARY
- Liquid line | Gas line 1 / 4” - 1 / 2”
- Fuses 16 A
- Signal Wires 4x1.5 No x mm²
-
Dimensions - Indoor unit
(WxDxH) 1.115x248x336 mm -
Dimensions - Outdoor unit
(WxDxH) 890x353x697 mm -
Net Weight -
Indoor/Outdoor 16.0/47.3 kg - Refrigerant/Charge R32/1.200 g
-
Outdoor Operation
Temperature Range - Cooling -20~43 °C -
Outdoor Operation
Temperature Range - Heating -20~24 °C
Useful files of the Dark series of air conditioners
Energy Labels, User - Installation Manuals - Wireless Remote Control - Wi-Fi, Product Fiche, CE Declaration, High Resolution Photos, Technical Specifications & Features
Find more
All you need to know about
Register now using your e-mail and get all the latest news in the world of air conditioning and more …