Professional air conditioners for absolute comfort and healthy atmosphere!

  • Absolutely clean and hygienic atmosphere thanks to - Ultraviolet Type C Technology and Ionizer
  • Wi-Fi functionality for easy management from anywhere and creation of personalised scripts according to your needs
  • Perfect conditions right where you want them
  • Energy savings of up to 70%
  • Upgraded clean air quality thanks to Antibacterial Function

Contact us

Eurovent"

Enjoy a perfectly clean and healthy atmosphere thank to the protection of the unit from the formation of malicious microorganisms. The process taking place inside the indoor unit removes humidity, that encourages bacteria spread, leading to fresh air distribution in your place!

Distributes cool/warm air to maximum area by moving horizontal flaps automatically.

The ultimate protection of the air conditioner, especially at areas with high humidity levels and increased corrosive possibility, such as islands and coastal areas, can now be achieved. The golden, anticorrosive coating of the outdoor unit’s refrigerant, protects against salty air, rain and other corrosive elements, ensuring the effective performance of the air conditioner and the extension of its lifeline. The golden coating of the indoor unit refrigerant, thanks to its antibacterial action, allows you to enjoy a perfectly clean and healthy atmosphere!

The self-cleaning feature cleans the indoor unit effectively, removing dust, pollen, and microorganisms that accumulate from air conditioning use. Additionally, it diminishes excess moisture within the indoor unit generated during cooling mode. To maintain peak performance and ensure proper maintenance, it's best to conduct internal cleaning every month.

With the new ECO mode on your remote controller, you can set your air conditioner to operate at the lowest cost, achieving maximum energy savings & enjoying the greatest conditions in your place.

The outdoor unit’s special design produces an efficient and effective heating operation even at -20°C.

This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.

Horizontal louver will automatically move to the same position as you set last time when the unit turned on.

Set the unit to start and stop automatically in a 24h period.

With the Sleep Mode, the air conditioner adjusts the room temperature for perfect sleeping conditions and great energy savings.

Set your favourite program as default according to the season and the weather and make your daily life easier! Choose your favourite mode, fan speed, temperature or louver movement and enjoy the atmosphere that you prefer when you get home, simply by touching a button.

If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.

Indoor unit will show error code “EC” and will stop automatically when refrigerant leakage is detected.

Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.

The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.

  • PF2UVI-09WFI / PF2UVO-09
  • Cooling Capacity 9.212 (1.706 - 10.577) Btu / h
  • Cooling Capacity Range 2.7 (0.5-3.1) kWatt
  • Heating Capacity 10.236 (1.706 - 11.260) Btu / h
  • Heating Capacity 3.0 (0.5-3.3) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14825)
  • Cooling
  • Pdesign 2.8 kW
  • Energy Class A++
  • SEER 6.1
  • Energy Consumption 161 kWh / year
  • Heating Middle Zone
  • Pdesign 2.7 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 945 kWh / year
  • Heating Warm Zone
  • Pdesign 3.4 kW
  • Energy Class A+++
  • SCOP 5.1
  • Energy Consumption 934 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 4.1 (0.6-6.3) Α
  • Current Input Heating 3.8 (0.8-6.2) Α
  • Power Input Cooling 0.90 (0.1-1.5) kW
  • Power Input Heating 0.85 (0.1-1.5) W
  • Air Flow Volume 600/500/400 m³ / h
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 26/33/39/44 db(A)
  • Sound Power Level Outdoor Unit 52 db(A)
  • Sound Power Level Indoor Unit 54 db(A)
  • Sound Power Level Outdoor Unit 62 db(A)
  • Dehumidifying Volume 1.3 L/h
  • Dehumidifying Volume 31.2 L/day
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4” / 3 / 8”
  • Fuses 10 A
  • Signal Wires 5 × 1.0 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    792x201x292 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    705×280x530 mm
  • Net Weight Indoor / Outdoor 8.5 / 21 kg
  • Refrigerant / Charge R32/560 g
  • Operation Temperature Range Outdoor Unit Cooling -15~49 °C
  • Operation Temperature Range Outdoor Unit Heating -20~32 °C
  • Hotel Menu Yes
  • PF2UVI-12WFI / PF2UVO-12
  • Cooling Capacity 11.942 (2.730-13.989) Btu / h
  • Cooling Capacity Range 3.5 (0.8-4.1) kWatt
  • Heating Capacity 12.966 (3.412-14.330) Btu / h
  • Heating Capacity 3.8 (1.0-4.2) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14825)
  • Cooling
  • Pdesign 3.5 kW
  • Energy Class A++
  • SEER 6.1
  • Energy Consumption 201 kWh / year
  • Heating Middle Zone
  • Pdesign 2.7 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 945 kWh / year
  • Heating Warm Zone
  • Pdesign 3.4 kW
  • Energy Class A+++
  • SCOP 5.1
  • Energy Consumption 914 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 5.4 (0.7-7.8) Α
  • Current Input Heating 5.1 (1.5-8.0) Α
  • Power Input Cooling 1.18 (0.1-1.6) kW
  • Power Input Heating 1.1 (0.3-1.6) W
  • Air Flow Volume 600/500/400 m³ / h
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 26/33/39/44 db(A)
  • Sound Power Level Outdoor Unit 52 db(A)
  • Sound Power Level Indoor Unit 54 db(A)
  • Sound Power Level Outdoor Unit 62 db(A)
  • Dehumidifying Volume 1.7 L/h
  • Dehumidifying Volume 40.8 L/day
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4” / 3 / 8”
  • Fuses 10 A
  • Signal Wires 5 × 1.0 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    792x201x292 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    705×280x530 mm
  • Net Weight Indoor / Outdoor 8.5 / 21 kg
  • Refrigerant / Charge R32/600 g
  • Operation Temperature Range Outdoor Unit Cooling -15~49 °C
  • Operation Temperature Range Outdoor Unit Heating -20~32 °C
  • Hotel Menu Yes
  • PF2UVI-18WFI / PF2UVO-18
  • Cooling Capacity 18.083 (4.436 - 19.448) Btu / h
  • Cooling Capacity Range 5.3 (1.3-5.7) kWatt
  • Heating Capacity 18.083 (4.436 - 18.766) Btu / h
  • Heating Capacity 5.3 (1.3-5.5) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14825)
  • Cooling
  • Pdesign 5.3 kW
  • Energy Class A++
  • SEER 6.8
  • Energy Consumption 273 kWh / year
  • Heating Middle Zone
  • Pdesign 3.9 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 1.365 kWh / year
  • Heating Warm Zone
  • Pdesign 4.3 kW
  • Energy Class A+++
  • SCOP 5.2
  • Energy Consumption 1.158 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 7.8 (2.2-9.3) Α
  • Current Input Heating 6.5 (2.0-8.0) Α
  • Power Input Cooling 1.65 (0.29-2.1) kW
  • Power Input Heating 1.47 (0.25-1.8) W
  • Air Flow Volume 850/650/550 m³ / h
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 30/36/41/47 db(A)
  • Sound Power Level Outdoor Unit 56 db(A)
  • Sound Power Level Indoor Unit 59 db(A)
  • Sound Power Level Outdoor Unit 62 db(A)
  • Dehumidifying Volume 2.5 L/h
  • Dehumidifying Volume 60 L/day
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4” / 1 / 2”
  • Fuses 16 A
  • Signal Wires 5 × 1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    940x224x316 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    785×300x555 mm
  • Net Weight Indoor / Outdoor 11 / 27 kg
  • Refrigerant / Charge R32/850 g
  • Operation Temperature Range Outdoor Unit Cooling -15~49 °C
  • Operation Temperature Range Outdoor Unit Heating -20~32 °C
  • Hotel Menu Yes
  • PF2UVI-24WFI / PF2UVO-24
  • Cooling Capacity 24.566 (6.142 - 25.248) Btu / h
  • Cooling Capacity Range 7.2 (1.8-7.4) kWatt
  • Heating Capacity 24.566 (6.142 - 27.296) Btu / h
  • Heating Capacity 7.2 (1.8-7.4) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14825)
  • Cooling
  • Pdesign 6.7 kW
  • Energy Class A++
  • SEER 6.5
  • Energy Consumption 359 kWh / year
  • Heating Middle Zone
  • Pdesign 5.7 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 1.950 kWh / year
  • Heating Warm Zone
  • Pdesign 7.0 kW
  • Energy Class A+++
  • SCOP 5.2
  • Energy Consumption 1.859 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 10.0 (1.0-12.0) Α
  • Current Input Heating 9.5 (1.0-11.0) Α
  • Power Input Cooling 2.2 (0.23-2.76) kW
  • Power Input Heating 2.2 (0.23-2.53) W
  • Air Flow Volume 1300/1010/870 m³ / h
  • Noise Level Indoor Unit (Silent / Low / Med / Hi) 31/37/43/48 db(A)
  • Sound Power Level Outdoor Unit 58 db(A)
  • Sound Power Level Indoor Unit 63 db(A)
  • Sound Power Level Outdoor Unit 66 db(A)
  • Dehumidifying Volume 3.1 L/h
  • Dehumidifying Volume 74.4 L/day
  • Compressor Type ROTARY
  • Liquid Line / Gas Line 1 / 4” / 5 / 8”
  • Fuses 16 A
  • Signal Wires 5 × 1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    1.132x232x330 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    900×350x700 mm
  • Net Weight Indoor / Outdoor 14 / 39 kg
  • Refrigerant / Charge R32 / 1.300 g
  • Operation Temperature Range Outdoor Unit Cooling -15~49 °C
  • Operation Temperature Range Outdoor Unit Heating -20~32 °C
  • Hotel Menu Yes

Useful files of the Professional (PF2UV) series of air conditioners

Energy Labels, User - Installation Manuals - Wireless Remote Control - Wi-Fi, Product Fiche, CE Declaration, High Resolution Photos, Technical Specifications & Features

Find more

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …