Matrix Split Type heat pumps for high performance, energy saving & ultimate comfort!

  • Energy class A+++ for saving energy and money with excellent performance
  • Excellent operation even in extreme outdoor temperatures
  • Inlet water up to 65°C for connection of radiators
  • Complete Central Control with simple usage due to the touch control of your device, featuring a Multilanguage Menu with various functions
  • Set up the device via Wi-Fi
  • Equipped with anti-icing bottom base resistor on the outdoor unit for operation at low temperatures
  • Two levels of quiet operation for reduced noise

Contact us

Maintain pristine quality of the water tank’s DHW and eliminate germs and bacteria by increasing the temperature of the water in it up to 70⁰C.

You can select the Fast DHW Function for the unit to produce DHW when there is a need for immediate hot water production.

With the inclusion of All DC Inverter technology, Inventor heat pumps operate at the ideal settings according to the constantly changing consumption needs, operating at the lowest possible noise levels while at the same time saving energy.

Ability to control a secondary external heating source (existing oil boiler, electric resistance, etc.) for parallel operation with the heat pump.

Designed as environmental friendly, Inventor heat pumps can connect with a Smart City’s Smart Grid. Through their connection with the Smart Grid, the heat pumps can automatically alter their operation to activate the DHW production when there is excess energy available or to restrict their operation when the electricity grid is overtaxed, saving energy and helping protect the environment.

Protect your home's floor thanks to the underfloor drying function, which can gradually increase the underfloor heating temperature to avoid damage to the floor and for a smoother transition to heating mode. The Floor Drying Up function is an additional solution for the installer, as it helps to remove any residual moisture that may occur when installing new underfloor heating circuits, thus protecting the new installation and ensuring better and more efficient use of the heat pump.

Ensure energy savings, comfort and flexibility. The heat pumps have the possibility of controlling 2 heating zones, for example application with radiators and underfloor heating.

Reduce energy consumption while saving money even when away from home with the Holiday Away mode. You can additionally program the heat pump with different operation settings through the Holiday Home mode, to activate quick and easy when your home activity changes from your typical daily schedule.

Connect up to 16 heat pumps with your building management system through Modbus RTU protocol to fully incorporate to your smart house/building and achieve complete control of the environment of your space.

Inventor Integrated Split Type Heat Pumps (All in One) are the ideal choice for easy and stress-free installation. Thanks to the all-in-one design and the built-I water tank, there is no need of connection of the unit to an external water tank device. The installation becomes even easier, as the height difference between the indoor and outdoor unit can be up to 20 meters and the total piping length up to 30 meters.

Equipped with a reliable water pump from Wilo or Grundfos, with lift up to 9m, Inventor Heat Pumps provide higher efficiency and guarantee optimal operation.

The unit is fully equipped with all hydraulic parts offering ease of installation.

The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.

In case of a power failure, the heat pump will automatically restart according to the previous settings.

  • ATS04S/HU060S3
  • Heating
    at Αmbient Temperature 7°C
    Average
  • Water temperature 35°C
  • Capacity 4.25 kW
  • Rated input 0.82 kW
  • COP 5.2
  • Water temperature 55°C
  • Capacity 4.4 kW
  • Rated input 1.49 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 4.5 kW
  • Rated input 0.81 kW
  • EER 5.55
  • Water temperature 7°C
  • Capacity 4.7 kW
  • Rated input 1.36 kW
  • EER 3.45
  • Seasonal space heating
    energy efficiency class
    Average
  • Water outlet at 35⁰C
  • ηs 191 %
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs 129 %
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.85
  • Water outlet at 55⁰C 3.31
  • SEER
  • Water outlet at 7⁰C 4.99
  • Water outlet at 18⁰C 7.77
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 18/12 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.5 up to 15m
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 1/4 | 5/8 | R1 inner dimension
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Signal Wires 3x1.0 shielded No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)
  • Outdoor 56/44/39 dB(A)
  • Indoor 38/28 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.008×712×426 mm
  • Indoor 420x790x270 mm
  • Net weight ODU/IDU 60/43 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW 30~60 tank
  • ATS06S/HU060S3
  • Heating
    at Αmbient Temperature 7°C
    Average
  • Water temperature 35°C
  • Capacity 6.2 kW
  • Rated input 1.24 kW
  • COP 5.0
  • Water temperature 55°C
  • Capacity 6.0 kW
  • Rated input 2.0 kW
  • COP 3.0
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 6.55 kW
  • Rated input 1.34 kW
  • EER 4.90
  • Water temperature 7°C
  • Capacity 7.0 kW
  • Rated input 2.33 kW
  • EER 3.00
  • Seasonal space heating
    energy efficiency class
    Average
  • Water outlet at 35⁰C
  • ηs 195 %
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs 138 %
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.95
  • Water outlet at 55⁰C 3.52
  • SEER
  • Water outlet at 7⁰C 5.34
  • Water outlet at 18⁰C 8.21
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 18/14 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.5 up to 15m
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 1/4 | 5/8 | R1 inner dimension
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Signal Wires 3x1.0 shielded No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)
  • Outdoor 58/45/40 dB(A)
  • Indoor 38/28 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.008×712×426 mm
  • Indoor 420x790x270 mm
  • Net weight ODU/IDU 60/43 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW 30~60 tank
  • ATS08S/HU100S3
  • Heating
    at Αmbient Temperature 7°C
    Average
  • Water temperature 35°C
  • Capacity 8.3 kW
  • Rated input 1.6 kW
  • COP 5.2
  • Water temperature 55°C
  • Capacity 7.5 kW
  • Rated input 2.36 kW
  • COP 3.18
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 8.4 kW
  • Rated input 1.66 kW
  • EER 5.05
  • Water temperature 7°C
  • Capacity 7.4 kW
  • Rated input 2.19 kW
  • EER 3.38
  • Seasonal space heating
    energy efficiency class
    Average
  • Water outlet at 35⁰C
  • ηs 205 %
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs 131 %
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 5.21
  • Water outlet at 55⁰C 3.36
  • SEER
  • Water outlet at 7⁰C 5.83
  • Water outlet at 18⁰C 8.95
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 19/16 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.65 up to 15m
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inner dimension
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Signal Wires 3x1.0 shielded No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)
  • Outdoor 59/46/41 dB(A)
  • Indoor 42/30 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 420x790x270 mm
  • Net weight ODU/IDU 78.5/43 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW 10~60 tank
  • ATS10S/HU100S3
  • Heating
    at Αmbient Temperature 7°C
    Average
  • Water temperature 35°C
  • Capacity 10.0 kW
  • Rated input 2.0 kW
  • COP 5.0
  • Water temperature 55°C
  • Capacity 9.5 kW
  • Rated input 3.06 kW
  • COP 3.1
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 10.0 kW
  • Rated input 2.08 kW
  • EER 4.8
  • Water temperature 7°C
  • Capacity 8.2 kW
  • Rated input 2.48 kW
  • EER 3.3
  • Seasonal space heating
    energy efficiency class
    Average
  • Water outlet at 35⁰C
  • ηs 204 %
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs 136 %
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 5.19
  • Water outlet at 55⁰C 3.49
  • SEER
  • Water outlet at 7⁰C 5.98
  • Water outlet at 18⁰C 8.78
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 19/17 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.65 up to 15m
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inner dimension
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Signal Wires 3x1.0 shielded No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)
  • Outdoor 60/49/41 dB(A)
  • Indoor 42/30 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 420x790x270 mm
  • Net weight ODU/IDU 78.5/43 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW 10~60 tank
  • ATS12S/HU160S3
  • Heating
    at Αmbient Temperature 7°C
    Average
  • Water temperature 35°C
  • Capacity 12.1 kW
  • Rated input 2.44 kW
  • COP 4.95
  • Water temperature 55°C
  • Capacity 12.0 kW
  • Rated input 3.87 kW
  • COP 3.1
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 12.0 kW
  • Rated input 3.0 kW
  • EER 4.0
  • Water temperature 7°C
  • Capacity 11.6 kW
  • Rated input 4.22 kW
  • EER 2.75
  • Seasonal space heating
    energy efficiency class
    Average
  • Water outlet at 35⁰C
  • ηs 189 %
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs 135 %
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.81
  • Water outlet at 55⁰C 3.45
  • SEER
  • Water outlet at 7⁰C 4.89
  • Water outlet at 18⁰C 7.1
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 30/25 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.84 up to 15m
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inner dimension
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x25 (bipolar fuse kinetic) No x Α
  • Signal Wires 3x1.0 shielded No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)
  • Outdoor 64/50/43 dB(A)
  • Indoor 43/32 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 420x790x270 mm
  • Net weight ODU/IDU 100/45 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW 10~60 tank
  • ATS14S/HU160S3
  • Heating
    at Αmbient Temperature 7°C
    Average
  • Water temperature 35°C
  • Capacity 14.5 kW
  • Rated input 3.09 kW
  • COP 4.7
  • Water temperature 55°C
  • Capacity 13.8 kW
  • Rated input 4.60 kW
  • COP 3.0
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 13.50 kW
  • Rated input 3.75 kW
  • EER 3.60
  • Water temperature 7°C
  • Capacity 12.7 kW
  • Rated input 4.98 kW
  • EER 2.55
  • Seasonal space heating
    energy efficiency class
    Average
  • Water outlet at 35⁰C
  • ηs 185 %
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs 135 %
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.72
  • Water outlet at 55⁰C 3.47
  • SEER
  • Water outlet at 7⁰C 4.86
  • Water outlet at 18⁰C 6.9
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3 / 1 kW/Ph
  • MOP/MCA 30/26 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.84 up to 15m
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inner dimension
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x32 (bipolar fuse kinetic) No x Α
  • Signal Wires 3x1.0 shielded No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)
  • Outdoor 65/51/43 dB(A)
  • Indoor 43/32 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 420x790x270 mm
  • Net weight ODU/IDU 96/39 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW 10~60 tank
  • ATS16S/HU160S3
  • Heating
    at Αmbient Temperature 7°C
    Average
  • Water temperature 35°C
  • Capacity 16.0 kW
  • Rated input 3.56 kW
  • COP 4.50
  • Water temperature 55°C
  • Capacity 16.0 kW
  • Rated input 5.52 kW
  • COP 2.90
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 14.90 kW
  • Rated input 4.38 kW
  • EER 3.40
  • Water temperature 7°C
  • Capacity 14.0 kW
  • Rated input 5.71 kW
  • EER 2.45
  • Seasonal space heating
    energy efficiency class
    Average
  • Water outlet at 35⁰C
  • ηs 182 %
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs 133 %
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.62
  • Water outlet at 55⁰C 3.41
  • SEER
  • Water outlet at 7⁰C 4.69
  • Water outlet at 18⁰C 6.75
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3 / 1 kW/Ph
  • MOP/MCA 30/27 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.84 up to 15m
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inner dimension
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x32 (bipolar fuse kinetic) No x Α
  • Signal Wires 3x1.0 shielded No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)
  • Outdoor 68/54/43 dB(A)
  • Indoor 43/32 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 420x790x270 mm
  • Net weight ODU/IDU 96/39 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW 10~60 tank
  • ATS12T/HU160T9
  • Heating
    at Αmbient Temperature 7°C
    Average
  • Water temperature 35°C
  • Capacity 12.1 kW
  • Rated input 2.44 kW
  • COP 4.95
  • Water temperature 55°C
  • Capacity 12.0 kW
  • Rated input 3.87 kW
  • COP 3.10
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 12.00 kW
  • Rated input 3.00 kW
  • EER 4.00
  • Water temperature 7°C
  • Capacity 11.6 kW
  • Rated input 4.22 kW
  • EER 2.75
  • Seasonal space heating
    energy efficiency class
    Average
  • Water outlet at 35⁰C
  • ηs 189 %
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs 135 %
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.81
  • Water outlet at 55⁰C 3.45
  • SEER
  • Water outlet at 7⁰C 4.86
  • Water outlet at 18⁰C 7.04
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater 9 / 3 kW/Ph
  • MOP/MCA 14/10 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.84 up to 15m
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inner dimension
  • Indoor Unit Fuses 4x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 4x20 (bipolar fuse kinetic) No x Α
  • Signal Wires 3x1.0 shielded No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)
  • Outdoor 64/50/43 dB(A)
  • Indoor 43/32 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 420x790x270 mm
  • Net weight ODU/IDU 112/45 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW 10~60 tank
  • ATS14T/HU160T9
  • Heating
    at Αmbient Temperature 7°C
    Average
  • Water temperature 35°C
  • Capacity 14.5 kW
  • Rated input 3.09 kW
  • COP 4.7
  • Water temperature 55°C
  • Capacity 13.8 kW
  • Rated input 4.6 kW
  • COP 3.0
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 13.5 kW
  • Rated input 3.75 kW
  • EER 3.6
  • Water temperature 7°C
  • Capacity 12.7 kW
  • Rated input 4.98 kW
  • EER 2.55
  • Seasonal space heating
    energy efficiency class
    Average
  • Water outlet at 35⁰C
  • ηs 185 %
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs 135 %
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.72
  • Water outlet at 55⁰C 3.47
  • SEER
  • Water outlet at 7⁰C 4.83
  • Water outlet at 18⁰C 6.85
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater 9 / 3 kW/Ph
  • MOP/MCA 14/11 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.84 up to 15m
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inner dimension
  • Indoor Unit Fuses 4x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 4x20 (quadpolar fuse kinetic) No x Α
  • Signal Wires 3x1.0 shielded No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)
  • Outdoor 65/51/43 dB(A)
  • Indoor 43/32 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 420x790x270 mm
  • Net weight ODU/IDU 116/45 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW 10~60 tank
  • ATS16T/HU160T9
  • Heating
    at Αmbient Temperature 7°C
    Average
  • Water temperature 35°C
  • Capacity 16.0 kW
  • Rated input 3.56 kW
  • COP 4.5
  • Water temperature 55°C
  • Capacity 16.0 kW
  • Rated input 5.52 kW
  • COP 2.9
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 14.9 kW
  • Rated input 4.38 kW
  • EER 3.4
  • Water temperature 7°C
  • Capacity 14.0 kW
  • Rated input 5.71 kW
  • EER 2.45
  • Seasonal space heating
    energy efficiency class
    Average
  • Water outlet at 35⁰C
  • ηs 182 %
  • Energy Class A+++
  • Water outlet at 55⁰C
  • ηs 133 %
  • Energy Class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.62
  • Water outlet at 55⁰C 3.41
  • SEER
  • Water outlet at 7⁰C 4.67
  • Water outlet at 18⁰C 6.71
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater 9 / 3 kW/Ph
  • MOP/MCA 14/12 A
  • Compressor
  • Type Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume R32/1.84 up to 15m
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inner dimension
  • Indoor Unit Fuses 4x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 4x20 (quadpolar fuse kinetic) No x Α
  • Signal Wires 3x1.0 shielded No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)
  • Outdoor 68/55/43 dB(A)
  • Indoor 43/32 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 420x790x270 mm
  • Net weight ODU/IDU 116/45 kg
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~30 ⁰C
  • Heating 12~65 ⁰C
  • DHW 10~60 tank

Useful files of Matrix Split Type Heat Pumps

Energy Labels, User - Installation Manuals - Wireless Remote Control - Wi-Fi, Product Fiche, CE Declaration, High Resolution Photos, Databook

Contact us

Find more

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …