Integrated Split Type Heat Pumps (All in One), Complete solution for guaranteed results!

  • Advanced design and easy installation
  • Complete solution which guarantees comfort and space saving
  • Ready to use system with secure results
  • Built-in indoor unit which upgrades your space
  • A+++ energy class for high performance and energy saving
  • High efficiency even at low outdoor ambient temperatures (-25⁰C)
  • Central control with touch wired controller for easy usage and a variety of functions

Contact us

Through the smart Wi-Fi management, you get to create the environment you desire, from anywhere. Free download the Comfort Home app from Google Play or App Store and save energy operating your appliance through your smartphone or tablet.

The heat pump units are designed with pre-installed heating belts located on the chassis and the compressor to ensure their protected operation even at extreme weather conditions, a longer operation life, and provide high efficiency and stellar heating conditions quickly and effectively.

Reduce the heat pump noise levels even further by selecting between the two different levels of silent operation.

Maintain pristine quality of the water tank’s DHW and eliminate germs and bacteria by increasing the temperature of the water in it up to 70⁰C.

You can select the Fast DHW Function for the unit to produce DHW when there is a need for immediate hot water production.

With the inclusion of All DC Inverter technology, Inventor heat pumps operate at the ideal settings according to the constantly changing consumption needs, operating at the lowest possible noise levels while at the same time saving energy.

Ability to control a secondary external heating source (existing oil boiler, electric resistance, etc.) for parallel operation with the heat pump.

Designed as environmental friendly, Inventor heat pumps can connect with a Smart City’s Smart Grid. Through their connection with the Smart Grid, the heat pumps can automatically alter their operation to activate the DHW production when there is excess energy available or to restrict their operation when the electricity grid is overtaxed, saving energy and helping protect the environment.

Protect your home's floor thanks to the underfloor drying function, which can gradually increase the underfloor heating temperature to avoid damage to the floor and for a smoother transition to heating mode. The Floor Drying Up function is an additional solution for the installer, as it helps to remove any residual moisture that may occur when installing new underfloor heating circuits, thus protecting the new installation and ensuring better and more efficient use of the heat pump.

Ensure energy savings, comfort and flexibility. The heat pumps have the possibility of controlling 2 heating zones, for example application with radiators and underfloor heating.

Reduce energy consumption while saving money even when away from home with the Holiday Away mode. You can additionally program the heat pump with different operation settings through the Holiday Home mode, to activate quick and easy when your home activity changes from your typical daily schedule.

Connect up to 16 heat pumps with your building management system through Modbus RTU protocol to fully incorporate to your smart house/building and achieve complete control of the environment of your space.

In case of a power failure, the heat pump will automatically restart according to the previous settings.

  • ATS04S/
    HU100WT190S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 4.25 kW
  • Rated input 0.82 kW
  • COP 5.20
  • Water temperature 55°C
  • Capacity 4.4 kW
  • Rated input 1.49 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 4.5 kW
  • Rated input 0.81 kW
  • EER 5.55
  • Water temperature 7°C
  • Capacity 4.7 kW
  • Rated input 1.36 kW
  • EER 3.45
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 191
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 129.5
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.85
  • Water outlet at 55⁰C 3.31
  • SEER
  • Water outlet at 7⁰C 4.98
  • Water outlet at 18⁰C 7.77
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 18/12 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.50 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 1/4 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 56/44/39 dB(A)
  • Indoor 38/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.008x712x426 mm
  • Indoor 600x1.683x600 mm
  • Net weight Outdoor/Indoor 58/140 kg
  • Domestic Hot Water Tank
  • Volume 190 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS04S/
    HU100WT240S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 4.25 kW
  • Rated input 0.82 kW
  • COP 5.20
  • Water temperature 55°C
  • Capacity 4.4 kW
  • Rated input 1.49 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 4.5 kW
  • Rated input 0.81 kW
  • EER 5.55
  • Water temperature 7°C
  • Capacity 4.7 kW
  • Rated input 1.36 kW
  • EER 3.45
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 191
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 129.5
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.85
  • Water outlet at 55⁰C 3.31
  • SEER
  • Water outlet at 7⁰C 4.98
  • Water outlet at 18⁰C 7.77
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 18/12 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.50 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 1/4 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 56/44/39 dB(A)
  • Indoor 38/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.008x712x426 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 58/157 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS06S/
    HU100WT190S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 6.2 kW
  • Rated input 1.24 kW
  • COP 5.0
  • Water temperature 55°C
  • Capacity 6.0 kW
  • Rated input 2.03 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 6.55 kW
  • Rated input 1.34 kW
  • EER 4.9
  • Water temperature 7°C
  • Capacity 7.0 kW
  • Rated input 2.33 kW
  • EER 3.00
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 195
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 137.9
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.95
  • Water outlet at 55⁰C 3.52
  • SEER
  • Water outlet at 7⁰C 5.31
  • Water outlet at 18⁰C 8.25
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 18/14 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.50 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 1/4 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 58/45/40 dB(A)
  • Indoor 38/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.008x712x426 mm
  • Indoor 600x1.683x600 mm
  • Net weight Outdoor/Indoor 58/140 kg
  • Domestic Hot Water Tank
  • Volume 190 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS06S/
    HU100WT240S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 6.2 kW
  • Rated input 1.24 kW
  • COP 5.0
  • Water temperature 55°C
  • Capacity 6.0 kW
  • Rated input 2.03 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 6.55 kW
  • Rated input 1.34 kW
  • EER 4.9
  • Water temperature 7°C
  • Capacity 7.0 kW
  • Rated input 2.33 kW
  • EER 3.00
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 195
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 137.9
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.95
  • Water outlet at 55⁰C 3.52
  • SEER
  • Water outlet at 7⁰C 5.31
  • Water outlet at 18⁰C 8.25
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 18/14 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.50 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 1/4 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 58/45/40 dB(A)
  • Indoor 38/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.008x712x426 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 58/157 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS08S/
    HU100WT190S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 8.3 kW
  • Rated input 1.6 kW
  • COP 5.2
  • Water temperature 55°C
  • Capacity 7.5 kW
  • Rated input 2.36 kW
  • COP 3.18
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 8.4 kW
  • Rated input 1.66 kW
  • EER 5.05
  • Water temperature 7°C
  • Capacity 7.4 kW
  • Rated input 2.19 kW
  • EER 3.38
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 205.6
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 131.5
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 5.22
  • Water outlet at 55⁰C 3.36
  • SEER
  • Water outlet at 7⁰C 5.83
  • Water outlet at 18⁰C 8.95
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 19/16 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.65 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 59/46/41 dB(A)
  • Indoor 40/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.683x600 mm
  • Net weight Outdoor/Indoor 75/140 kg
  • Domestic Hot Water Tank
  • Volume 190 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS08S/
    HU100WT240S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 8.3 kW
  • Rated input 1.6 kW
  • COP 5.2
  • Water temperature 55°C
  • Capacity 7.5 kW
  • Rated input 2.36 kW
  • COP 3.18
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 8.4 kW
  • Rated input 1.66 kW
  • EER 5.05
  • Water temperature 7°C
  • Capacity 7.4 kW
  • Rated input 2.19 kW
  • EER 3.38
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 205.6
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 131.5
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 5.22
  • Water outlet at 55⁰C 3.36
  • SEER
  • Water outlet at 7⁰C 5.83
  • Water outlet at 18⁰C 8.95
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 19/16 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.65 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 59/46/41 dB(A)
  • Indoor 40/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 75/157 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS10S/
    HU100WT190S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 10.0 kW
  • Rated input 2.0 kW
  • COP 5.0
  • Water temperature 55°C
  • Capacity 9.5 kW
  • Rated input 3.06 kW
  • COP 3.1
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 10.0 kW
  • Rated input 2.08 kW
  • EER 4.8
  • Water temperature 7°C
  • Capacity 8.2 kW
  • Rated input 2.48 kW
  • EER 3.3
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 204.8
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 136.6
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 5.2
  • Water outlet at 55⁰C 3.49
  • SEER
  • Water outlet at 7⁰C 5.96
  • Water outlet at 18⁰C 8.8
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 19/17 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.65 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 60/49/41 dB(A)
  • Indoor 40/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.683x600 mm
  • Net weight Outdoor/Indoor 75/140 kg
  • Domestic Hot Water Tank
  • Volume 190 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS10S/
    HU100WT240S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 10.0 kW
  • Rated input 2.0 kW
  • COP 5.0
  • Water temperature 55°C
  • Capacity 9.5 kW
  • Rated input 3.06 kW
  • COP 3.1
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 10.0 kW
  • Rated input 2.08 kW
  • EER 4.8
  • Water temperature 7°C
  • Capacity 8.2 kW
  • Rated input 2.48 kW
  • EER 3.3
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 204.8
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 136.6
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 5.2
  • Water outlet at 55⁰C 3.49
  • SEER
  • Water outlet at 7⁰C 5.96
  • Water outlet at 18⁰C 8.8
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 19/17 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.65 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x20 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 60/49/41 dB(A)
  • Indoor 40/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 75/157 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS12S/
    HU160WT240S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 12.1 kW
  • Rated input 2.44 kW
  • COP 4.95
  • Water temperature 55°C
  • Capacity 11.9 kW
  • Rated input 3.87 kW
  • COP 3.05
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 12.0 kW
  • Rated input 3.0 kW
  • EER 4.0
  • Water temperature 7°C
  • Capacity 11.6 kW
  • Rated input 4.22 kW
  • EER 2.75
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 189.4
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 135.1
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.81
  • Water outlet at 55⁰C 3.45
  • SEER
  • Water outlet at 7⁰C 4.93
  • Water outlet at 18⁰C 7.14
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 30/25 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x25 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 64/50/43 dB(A)
  • Indoor 42/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 97/159 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS14S/
    HU160WT240S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 14.5 kW
  • Rated input 3.09 kW
  • COP 4.70
  • Water temperature 55°C
  • Capacity 13.8 kW
  • Rated input 4.60 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 13.5 kW
  • Rated input 3.74 kW
  • EER 3.61
  • Water temperature 7°C
  • Capacity 12.7 kW
  • Rated input 4.98 kW
  • EER 2.55
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 185.7
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 135.6
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.81
  • Water outlet at 55⁰C 3.45
  • SEER
  • Water outlet at 7⁰C 4.81
  • Water outlet at 18⁰C 6.86
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 30/26 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x32 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 65/51/43 dB(A)
  • Indoor 44/25 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 97/159 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS16S/
    HU160WT240S3
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 16.0 kW
  • Rated input 3.56 kW
  • COP 4.50
  • Water temperature 55°C
  • Capacity 16.0 kW
  • Rated input 5.52 kW
  • COP 2.85
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 14.2 kW
  • Rated input 3.94 kW
  • EER 3.61
  • Water temperature 7°C
  • Capacity 14.0 kW
  • Rated input 5.71 kW
  • EER 2.45
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 181.7
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 133.3
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.72
  • Water outlet at 55⁰C 3.47
  • SEER
  • Water outlet at 7⁰C 4.6
  • Water outlet at 18⁰C 6.67
  • Power supply 220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater 3/1 kW/Ph
  • MOP/MCA 30/27 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 2x20 (bipolar fuse kinetic) No x Α
  • External unit fuses 2x32 (bipolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 68/54/43 dB(A)
  • Indoor 44/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 97/159 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS12T/
    HU160WT240T9
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 12.1 kW
  • Rated input 2.44 kW
  • COP 4.95
  • Water temperature 55°C
  • Capacity 11.9 kW
  • Rated input 3.87 kW
  • COP 3.05
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 12.0 kW
  • Rated input 3.00 kW
  • EER 4.0
  • Water temperature 7°C
  • Capacity 11.6 kW
  • Rated input 4.22 kW
  • EER 2.75
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 189.3
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 135.1
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.72
  • Water outlet at 55⁰C 3.47
  • SEER
  • Water outlet at 7⁰C 4.83
  • Water outlet at 18⁰C 7.0
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater 9/3 kW/Ph
  • MOP/MCA 14/10 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 4x16 (quadpolar fuse kinetic) No x Α
  • External unit fuses 4x16 (quadpolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 64/50/43 dB(A)
  • Indoor 42/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 112/159 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS14T/
    HU160WT240T9
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 14.5 kW
  • Rated input 3.09 kW
  • COP 4.7
  • Water temperature 55°C
  • Capacity 13.8 kW
  • Rated input 4.6 kW
  • COP 2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 13.5 kW
  • Rated input 3.74 kW
  • EER 3.61
  • Water temperature 7°C
  • Capacity 12.7 kW
  • Rated input 4.98 kW
  • EER 2.55
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 185.6
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 135.6
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.62
  • Water outlet at 55⁰C 3.41
  • SEER
  • Water outlet at 7⁰C 4.79
  • Water outlet at 18⁰C 6.81
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater 9/3 kW/Ph
  • MOP/MCA 14/11 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 4x16 (quadpolar fuse kinetic) No x Α
  • External unit fuses 4x16 (quadpolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 65/51/43 dB(A)
  • Indoor 44/25 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 112/159 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C
  • ATS16T/
    HU160WT240T9
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity 16.0 kW
  • Rated input 3.56 kW
  • COP 4.5
  • Water temperature 55°C
  • Capacity 16.0 kW
  • Rated input 5.52 kW
  • COP 2.85
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity 14.2 kW
  • Rated input 3.94 kW
  • EER 3.61
  • Water temperature 7°C
  • Capacity 14.0 kW
  • Rated input 5.71 kW
  • EER 2.45
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%) 181.6
  • class A+++
  • Water outlet at 55⁰C
  • ηs (%) 133.2
  • class A++
  • SCOP (Average)
  • Water outlet at 35⁰C 4.62
  • Water outlet at 55⁰C 3.41
  • SEER
  • Water outlet at 7⁰C 4.58
  • Water outlet at 18⁰C 6.63
  • Power supply 380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater 9/3 kW/Ph
  • MOP/MCA 14/12 A
  • Compressor
  • Tipo Twin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchanger Plate type
  • Pipe size
  • Liquid | Gas | Water 3/8 | 5/8 | R1 inch
  • Indoor Unit Fuses 4x16 (quadpolar fuse kinetic) No x Α
  • External unit fuses 4x16 (quadpolar fuse kinetic) No x Α
  • Power Supply Wire 3x1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor 68/55/43 dB(A)
  • Indoor 44/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor 1.118x865x523 mm
  • Indoor 600x1.943x600 mm
  • Net weight Outdoor/Indoor 112/159 kg
  • Domestic Hot Water Tank
  • Volume 240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure 10 bar
  • Material Stainless Steel
  • Outdoor air temperature range
  • Cooling -5~43 ⁰C
  • Heating -25~35 ⁰C
  • DHW -25~43 ⁰C
  • Water outlet temperature range
  • Cooling 5~25 ⁰C
  • Heating 25~65 ⁰C
  • DHW (tank) 30~60 ⁰C

Useful files of Matrix Split Integrated Type Heat Pumps

Energy Labels, User - Installation Manuals - Wireless Remote Control - Wi-Fi, Product Fiche, CE Declaration, High Resolution Photos, Databook

Contact us

Find more

All you need to know about

Register now using your e-mail and get all the latest news in the world of air conditioning and more …